Journal metrics

Journal metrics

  • CiteScore value: 1.27 CiteScore 1.27
  • SNIP value: 0.671 SNIP 0.671
  • SJR value: 0.561 SJR 0.561
  • IPP value: 1.19 IPP 1.19
  • Scimago H index value: 19 Scimago H index 19
Sci. Dril., 23, 39-46, 2017
https://doi.org/10.5194/sd-23-39-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 4.0 License.
Technical development
30 Nov 2017
Contamination tracer testing with seabed drills: IODP Expedition 357
Beth N. Orcutt1, Markus Bergenthal2, Tim Freudenthal2, David Smith3, Marvin D. Lilley4, Luzie Schnieders2, Sophie Green3, and Gretchen L. Früh-Green5 1Bigelow Laboratory for Ocean Sciences, East Boothbay, ME 04544, USA
2MARUM, University of Bremen, 28334 Bremen, Germany
3British Geological Survey, The Lyell Centre, Edinburgh, EH14 4AP, Scotland, UK
4School of Oceanography, University of Washington, Seattle, WA 98195, USA
5Institute for Geochemistry and Petrology, ETH Zürich, 8092 Zürich, Switzerland
Abstract. IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

Citation: Orcutt, B. N., Bergenthal, M., Freudenthal, T., Smith, D., Lilley, M. D., Schnieders, L., Green, S., and Früh-Green, G. L.: Contamination tracer testing with seabed drills: IODP Expedition 357, Sci. Dril., 23, 39-46, https://doi.org/10.5194/sd-23-39-2017, 2017.
Publications Copernicus
Download
Short summary
This paper describes a new tracer delivery system designed for use with seabed drills. The motivation for this system was the need to assess for possible seawater contamination of hard rock cores intended for microbiological and geochemical assessment. During IODP Expedition 357, the system was tested and proven to deliver a synthetic tracer at target saturating concentrations, which was useful for assessing sample contamination and handling procedures.
This paper describes a new tracer delivery system designed for use with seabed drills. The...
Share